GNU/Linux >> Linux Esercitazione >  >> Linux

Qual è l'interfaccia per le chiamate di sistema ARM e dove è definita nel kernel Linux?

Risposta più generica di quella che hai chiesto.

Su Linux il man syscall (2) è un buon inizio per scoprire come effettuare una chiamata di sistema in varie architetture.

Copiato da quella manpage:

Architecture calling conventions
    Every architecture has its own way of invoking and passing arguments
    to the kernel.  The details for various architectures are listed in
    the two tables below.

    The first table lists the instruction used to transition to kernel
    mode (which might not be the fastest or best way to transition to the
    kernel, so you might have to refer to vdso(7)), the register used to
    indicate the system call number, the register used to return the sys‐
    tem call result, and the register used to signal an error.

    arch/ABI    instruction           syscall #  retval  error    Notes
    ────────────────────────────────────────────────────────────────────
    alpha       callsys               v0         a0      a3       [1]
    arc         trap0                 r8         r0      -
    arm/OABI    swi NR                -          a1      -        [2]
    arm/EABI    swi 0x0               r7         r0      -
    arm64       svc #0                x8         x0      -
    blackfin    excpt 0x0             P0         R0      -
    i386        int $0x80             eax        eax     -
    ia64        break 0x100000        r15        r8      r10      [1]
    m68k        trap #0               d0         d0      -
    microblaze  brki r14,8            r12        r3      -
    mips        syscall               v0         v0      a3       [1]
    nios2       trap                  r2         r2      r7
    parisc      ble 0x100(%sr2, %r0)  r20        r28     -
    powerpc     sc                    r0         r3      r0       [1]
    riscv       scall                 a7         a0      -
    s390        svc 0                 r1         r2      -        [3]
    s390x       svc 0                 r1         r2      -        [3]
    superh      trap #0x17            r3         r0      -        [4]
    sparc/32    t 0x10                g1         o0      psr/csr  [1]
    sparc/64    t 0x6d                g1         o0      psr/csr  [1]
    tile        swint1                R10        R00     R01      [1]
    x86-64      syscall               rax        rax     -        [5]
    x32         syscall               rax        rax     -        [5]
    xtensa      syscall               a2         a2      -

    Notes:

        [1] On a few architectures, a register is used as a boolean (0
            indicating no error, and -1 indicating an error) to signal
            that the system call failed.  The actual error value is still
            contained in the return register.  On sparc, the carry bit
            (csr) in the processor status register (psr) is used instead
            of a full register.

        [2] NR is the system call number.

        [3] For s390 and s390x, NR (the system call number) may be passed
            directly with svc NR if it is less than 256.

        [4] On SuperH, the trap number controls the maximum number of
            arguments passed.  A trap #0x10 can be used with only 0-argu‐
            ment system calls, a trap #0x11 can be used with 0- or
            1-argument system calls, and so on up to trap #0x17 for
            7-argument system calls.

        [5] The x32 ABI uses the same instruction as the x86-64 ABI and
            is used on the same processors.  To differentiate between
            them, the bit mask __X32_SYSCALL_BIT is bitwise-ORed into the
            system call number for system calls under the x32 ABI.  Both
            system call tables are available though, so setting the bit
            is not a hard requirement.

    The second table shows the registers used to pass the system call
    arguments.

    arch/ABI      arg1  arg2  arg3  arg4  arg5  arg6  arg7  Notes
    ──────────────────────────────────────────────────────────────
    alpha         a0    a1    a2    a3    a4    a5    -
    arc           r0    r1    r2    r3    r4    r5    -
    arm/OABI      a1    a2    a3    a4    v1    v2    v3
    arm/EABI      r0    r1    r2    r3    r4    r5    r6
    arm64         x0    x1    x2    x3    x4    x5    -
    blackfin      R0    R1    R2    R3    R4    R5    -
    i386          ebx   ecx   edx   esi   edi   ebp   -
    ia64          out0  out1  out2  out3  out4  out5  -
    m68k          d1    d2    d3    d4    d5    a0    -
    microblaze    r5    r6    r7    r8    r9    r10   -
    mips/o32      a0    a1    a2    a3    -     -     -     [1]
    mips/n32,64   a0    a1    a2    a3    a4    a5    -
    nios2         r4    r5    r6    r7    r8    r9    -
    parisc        r26   r25   r24   r23   r22   r21   -
    powerpc       r3    r4    r5    r6    r7    r8    r9
    riscv         a0    a1    a2    a3    a4    a5    -
    s390          r2    r3    r4    r5    r6    r7    -
    s390x         r2    r3    r4    r5    r6    r7    -
    superh        r4    r5    r6    r7    r0    r1    r2
    sparc/32      o0    o1    o2    o3    o4    o5    -
    sparc/64      o0    o1    o2    o3    o4    o5    -
    tile          R00   R01   R02   R03   R04   R05   -
    x86-64        rdi   rsi   rdx   r10   r8    r9    -
    x32           rdi   rsi   rdx   r10   r8    r9    -
    xtensa        a6    a3    a4    a5    a8    a9    -

    Notes:

        [1] The mips/o32 system call convention passes arguments 5
            through 8 on the user stack.

    Note that these tables don't cover the entire calling convention—some
    architectures may indiscriminately clobber other registers not listed
    here.

Quindi dipende se il sistema utilizza OABI o EABI.

Quindi in EABI usi r7 per passare il numero della chiamata di sistema, usa r0-r6 per passare gli argomenti, usa SWI 0 per effettuare la chiamata di sistema, aspettati il ​​risultato in r0 .

In OABI tutto è uguale tranne che usi SWI <number> per effettuare una chiamata di sistema.


Nel mondo ARM, fai un software interrupt (meccanismo per segnalare il kernel) di supervisor call / svc (precedentemente chiamato SWI).

La sintassi dell'assembly ARM (UAL) è simile a questa:

SVC{<c>}{<q>} {#}<imm>

(In Linux devi passare #0)

Dovresti imbrogliare da altri progetti come bionic o uClibc.


Il disassemblaggio di hello world in n900 mostra svc #0

http://brnz.org/hbr/?m=201102


Linux
  1. Test di integrazione continui per il kernel Linux

  2. Qual è la giusta quantità di spazio di scambio per un moderno sistema Linux?

  3. Cos'è Linux? Una guida per utenti non tecnici

  4. Qual è la differenza tra chiamate probabili e improbabili nel kernel?

  5. Cosa fanno i parametri del kernel acpi_osi=linux e acpi_backlight=vendor?

Qual ​​è la differenza tra i kernel macOS e Linux

Qual è la differenza tra Linux e Unix?

Linux:come trovare le implementazioni delle chiamate di sistema del kernel Linux?

Che cosa sono le chiamate di sistema Linux e le funzioni di libreria?

I 15 migliori software econometrico e statistico per sistemi Linux

Quali sono le convenzioni di chiamata per le chiamate di sistema UNIX e Linux (e le funzioni dello spazio utente) su i386 e x86-64